UV-2600/2700UV-VIS SpectrophotometersC101-E121

Seite 2

Accessories have been prepared to accommodate a variety of applications such as temperature-controlled, micro-volume, and multisample measurements.Wit

Seite 3 - Double monochromator UV-2700

11Automated Data ProcessingAnalysis Correspondence ChartAfter spectra are measured, the software can perform data processing automatically in conjunc

Seite 4 - Enabling 8-Abs Measurements

A Wealth of Applications12Thickness Measurements of Cling FilmsBand Gap Measurements for Compound SemiconductorsDNA and Protein MeasurementsElectricit

Seite 5 - 8-Abs Photometric Range

13An aqueous solution of hexavalent chromium was colored with a diphenylcarbazide reagent, and the absorption spectrum was then checked. It is eviden

Seite 6 - Wavelength up to 1400 nm

UVProbe SoftwareAll-In-One SoftwareSpectrum ModulePhotometric ModuleReport GeneratorKinetics Module14UVProbe is an all-in-one software package equippe

Seite 7

A Variety of Data Processing and Calculation Functions15Data processing operations, such as peak detection and area calculation, and data conversion o

Seite 8 - Size Down

(Note) UVProbe software Ver. 2.00 or later is required.Optional SoftwareUVProbe Agent Software16The UVProbe Agent, which was developed for Shimadzu UV

Seite 9 - User-Friendly

17Color Measurement SoftwareThis software calculates color values of the measurement sample from the spectrum measured.This software measures the thic

Seite 10 - Accommodates Any Application

Accessories (Options)Cells18Unit: mmDescriptionSquare cellSquare cell with stopperSemi-micro cellSemi-micro black cellSupermicro black cellMicro black

Seite 11 - Analysis Correspondence Chart

19If using a 4-cell-type universalrectangular cell holder, use this as arreference-side cell holder if necessary.Holds two cylindrical cells with an o

Seite 12 - A Wealth of Applications

Experience the Precision Desired, in Any Situation

Seite 13 - 0.04, 0.02, and 0.01 mg/mL

Accessories (Options)20• Micro-volume samples can be measured. (Minimum sample volume: 50 μL to 100 μL)• Support for commercial microplates and mic

Seite 14 - UVProbe Software

21Constant-Temperature Cell Holder(Cat. No. 202-30858-04)• Temperature range: 5 °C to 90 °C (depends on the performance of the constant-temperature

Seite 15 - Methods as Standard

Accessories (Options)22• The aspirating nozzle is programmed to move in the X, Y, and Z (vertical) directions.• Up to eight sets of operational parame

Seite 16 - Optional Software

23Sample Pretreatment Automation Connection Kit(Cat. No. 206-80880-02)• The connection kit consists of a flow cell unit and connection cable. The

Seite 17 - Color Measurement Software

Accessories (Options)24• Samples as large as W100 × D160 × T15 mm can be readily measured. The minimum size is 7 mm in diameter.• Sample placement i

Seite 18 - Accessories (Options)

25• Capacity of 0.16 mL, 3 included ASR-3105 Absolute Reflectance Attachment, 5°ASR-3112 Absolute Reflectance Attachment, 12° ASR-3130 Absolute Reflec

Seite 19

Hardware SpecificationsInstallation Area Plan (UV-2600/2700)26ItemPhotometric system Photometric systemUV-2600Czerny-Turner mountingSingle monochromat

Seite 20

Software Specifications27(Note) UV Validation SoftwareUVProbe SoftwareOperatingSystemDataAcquisitionModesGeneralSpectrumModeDataProcessingin SpectrumM

Seite 21

UV-2600/2700Printed in Japan 3295-08106-30ANSThe contents of this brochure are subject to change without notice.SHIMADZU CORPORATION. International

Seite 22

Equipped with a single monochromator, providing low noise performance across a wide wavelength rangeEnables near-infrared measurements (up to 1400

Seite 23

Lo-Ray-Ligh grade diffraction gratingAchieves Ultra-Low Stray Light, Enabling 8-Abs Measurements4Conventional models provide 5-Abs coverage. Even high

Seite 24

Double monochromator UV-2700Performance with a Minimum 8-Abs Photometric RangeEquipped with a double monochromator that achieves ultra-low stray ligh

Seite 25 - Film Holder

Single monochromator UV-2600Integrating Sphere Enables Measurements to 1400 nmCapable of a Measurement Wavelength up to 1400 nmA key feature of the UV

Seite 26 - Installation Area Plan

7Transmission Measurements of Polycrystalline Silicon Using the ISR-2600Plus UV-2600Relative Diffuse Reflection Measurements of an Anti-Reflective Fi

Seite 27 - Software Specifications

28 % Size Reductionin Comparison toConventional Models28% Size DownConventional model (UV-2450/2550)600 mm450 mm120mm60mmCompact 450 mm Width Size8Wit

Seite 28 - JQA-0376

Even More Compact and User-FriendlyTo respond to feedback that conventional models are too large, we have challenged ourselves to maximize space savi